Advantel Optical Technology Co.Ltd
|
|
| |
|
|
|
|

|

|
Click to enlarge image
|
Model Number |
MW9076 |
| Products >>Test System
Equipment>> Anritsu MW9076 OTDR |
| | |
|
 |
MW9076Series Optical Time Domain
Reflectometer 1.31/1.45/1.55/1.625 μm (SM),
0.85/1.3 μm (GI)
Highest Performance, Functions, and Measuring SpeedMeasuring
Speed - 45 dB high dynamic range - 8 m short dead zone -
Simple measurement of chromatic dispersion from one end of optical
fiber - Measurement in 10 s (Full-Auto mode), 0.15 s real-time
sweep - Automatic execution of functions such as
wavelength/channel switching, file saving, printing, etc., just
by pressing Start key in repeat measurement mode - 5 cm high
resolution, 50,000 sampling points - 8.4 inch transparent type
TFT-LCD color display - 7.8 inch reflective type STN-LCD color
display for easy viewing under direct sunlight - Optional 4 or 8
optical channel selector - 6-hour battery life with
remaining-power display - Data read/write in Bellcore GR196 file
format |
| Model |
MW9076B |
MW9076C |
MW9076B1 |
MW9076J |
MW9076K |
MW9076D1 |
| Wavelength |
1310/1550 nm ±25 nm*1 |
1310/1550/1625 nm ±25 nm*1 |
1310/1550 nm ±25 nm*1 |
850 nm ±30 nm |
850/1300 nm ±30 nm |
1310/1450/1550/1625 nm ±3 nm*1 |
| Measurable optical fiber |
10/125 μm single-mode optical fiber
(ITU-T G.652) |
62.5/125 μm GI fiber*2 |
10/125 μm singlemode optical fiber (ITU-T
G.652) |
| Optical connector |
FC, SC, DIN, HMS-10/A, ST (replaceable,
PC type) |
FC, SC, DIN, ST (replaceable, PC
type) |
FC, SC, DIN, HMS- 10/A, ST (replaceable, PC
type) |
| Distance range |
1, 2.5, 5, 10, 25, 50, 100, 200, 250, 400
km |
1, 2.5, 5, 10, 25, 50, 100
km |
1, 2.5, 5, 10, 25, 50, 100, 200, 250, 400
km |
| Pulse width |
10, 20, 50, 100, 500, 1000, 2000, 4000,
10000, 20000 ns |
10, 20, 50, 100 ns |
10, 20, 50, 100 ns (0.85 μm) 10, 20, 50, 100,
500, 1000 ns (1.3 μm) |
10, 20, 50, 100, 500, 1000, 2000, 4000,
10000, 20000 ns |
Dynamic range*3 (S/N=1)
|
42.5 dB (1.31 μm) 40.5 dB (1.55 μm) *Typical
value: 45 dB (1.31 μm) 43 dB (1.55 μm)
|
41.5 dB (1.31 μm) 39.5 dB (1.55 μm) 37 dB (1.625
μm)
|
38 dB (1.31 μm) 36 dB (1.55 μm) *Typical
value: 40.5 dB (1.31 μm) 38.5 dB (1.55
μm)
|
21 dB |
21 dB (0.85 μm) 25 dB (1.3 μm)
|
34.5 dB (1.31 μm) 33.5 dB (1.45 μm) 32.5 dB (1.55
μm) 30.0 dB (1.625 μm) |
Dead zone (back-scattered
light)*4
|
8 m (1.31 μm) 9 m (1.55 μm)
|
28 m (1.31 μm) 29 m (1.55 μm) 212 m (1.625
μm)
|
28 m (1.31 μm) 29 m (1.55 μm)
|
27 m (deviation:±0.5 dB) 250 m (deviation:±0.1 dB)
|
27 m (0.85 μm, deviation: ±0.5 dB) 210 m (1.3
μm, deviation: ±0.5 dB) 250 m (deviation:±0.1 dB)
|
225 m |
| Dead zone 2(Fresnel reflection)*5 |
1.6 m
|
22 m |
23 m |
| Marker resolution |
0.05 to 800 m |
0.05 to 200 m |
0.05 to 800 m |
| Sampling resolution |
0.05 to 80 m |
0.05 to 20 m |
0.05 to 80 m |
| Sampling points*6 |
Quick mode: 5001, 6251 Normal mode:
20001, 25001 High mode: 40001, 50001 |
| Y-axis scale |
0.25, 0.5, 1, 2.5, 5, 10, 15 dB/div (15
dB/div is indicated only at Auto and Full Auto
measurement.) |
| IOR settings |
1.400000 to 1.699999 (0.000001
steps) |
Distance measurement accuracy |
±1 m ±3 x measurement distance x 10?
±marker resolution (excluding uncertainty caused by fiber
IOR) |
0.1 m ±3 x measurement distancex 10? ±marker
resolution (excluding uncertainty caused by fiber
IOR) |
| Loss measurement accuracy(linearity) |
±0.05 dB/dB or ±0.1 dB (whichever is
greater) |
| Return loss measurementaccuracy |
±2 dB
|
±4
dB |
±2
dB |
| Automatic measurement*7 |
Measurement items: Total loss, total
return loss. Each event distance, connection loss, return
loss, or reflection amount (displays in table
format) Threshold values Connection loss: 0.01 to 9.99
dB (in 0.01 dB steps), Return loss: 20 to 60 dB (in 0.1 dB
steps), Fiber-end: 1 to 99 dB (in 1 dB steps) Warning
values Splice connection loss: 0.1 to 10 dB (in 0.01 dB
steps), Connector connection loss: 0.1 to 10 dB (in 0.01 dB
steps), Return loss: 10 to 50 dB (in 0.1 dB steps), Fiber
loss: 0.01 to 10 dB (in 0.01 dB steps), Total loss: 0.1 to
60 dB (in 0.1 dB steps), Total return loss: 10 to 50 dB (in
0.1 dB steps), Average loss: 0.01 to 10 dB (in 0.01 dB
steps) Number of detected events: Up to 99 Automatic
setting: Distance range, pulse width, averaging count
(time) Measurement time: 260 s (in full automatic
measurement mode) Connection check: Automatic check of
front panel connector connection quality Communication
light check: Check for presence of communication light in
optical fiber to be measured |
| Manual measurement |
Measurement items: Transmission loss
and distance between 2 points, loss per unit length between 2
points, connection loss, return loss/reflection amount,
total return loss, average loss Real-time sweep: 0.1 to 0.2
second or